Automatic pond aerator controller


The automatic pond aerator controller can automatically detect the amount of dissolved oxygen in water and automatically control aerators work, and it can set different minimum dissolved oxygen for different species of fishes, guaranteeing dissolved oxygen under unsupervised to achieve the best fish and shrimp farming requirement. Replacing manual inspection of fatigue, with manual detection accuracy can not be compared. Only in the case of dissolved oxygen below the set standards, then use the aerator, which will save a lot of electricity, saving the cost of breeding for fish farmers. Modern farming needs high-tech equipment, so oxygen controller is most needed for fish farmers.

The automatic pond aerator controller is R & D by the fishery experts, who combine with much advice from a number of experienced aquaculture farmers, so it is designed for different varieties of ponds and water dissolved oxygen problems.

The equipment has the following six functions:

       Dissolved oxygen measurements is displayed in a separate window

       Temperature measurement is displayed in a separate window

       Oxygen limit adjustment buttons is displayed in a separate window

       Automatic start and stop control aerator

       Manually start and stop buttons control aerator

       Hypoxia alarm, power failure alarm

     

Five characteristics:

       Measuring distance, up to 400 meters, the best direct measurement points --- ponds center, to ensure the rationality of the measurement.

       Control power, up to 15 KW, without any external devices, can be directly controlled 3 to 5 aerators.

       High long-term accuracy, after each cleaning, it can be 360 days of continuous use (F-type), long-term assurance for control accuracy.

       Long life, oxygen electrode using gold, silver and other precious metals manufacturing, the normal life is up to 10 years.

       Built-in power failure alarm circuit.

   

 Key indicators:

       Power supply: 220V ± 10%

       Ambient temperature: 0 ~ 40 ℃;

       Relative humidity: less than 85%;

       Dissolved Oxygen Measurement range: 0.1 ~ 20.0mg / L

       DO measurement error: less than ± 0.5mg / L

       Temperature measuring range: 0 ~ 50 ℃

       Temperature measurement error: less than ± 0.5 ℃

       Control mode: Auto, Manual

       Display window: dissolved oxygen, oxygen limit temperature

       Measuring distance: 50 meters (can be extended to 400 meters)

       Control power: 15KW (F-type 15KW × 2)

       Stability: Every 360 days of continuous use after cleaning, long-term monitoring and control accuracy

       Packing size: 350 × 297 × 290 mm